2017 | AFC ACCOMPLISHMENTS 27 Figure 4. Pressure and temperature histories for in-cell LOCA integral test Zr4-26. A Severe Accident Test Station (SATS) capable of examining the oxidation kinetics and accident response of irradiated fuel and cladding materials for design basis accident (DBA) and beyond design basis accident (BDBA) scenarios has been successfully installed and demonstrated in the Irradiated Fuels Examination Laboratory, a hot cell facility at Oak Ridge National Laboratory.