b'efficiencies. Research on accidentencourage development of next- Figure 1. Zry-4 pressurized to 9.69 MPa tolerant fuel claddings inevitablygeneration reactors for the Unitedand heated at 5C/s, a. Digital image improves safety margin for designStates fleet. correlation camera image with hoop strain map overlaid, b. Hoop strain line basis accidents, but the additionalprofile as a function of temperature. cost savings through achievingTemperature was controlled via higher fuel burnups is expected tothermocouples and monitored with fiberoptic sensors design of the TWIST LOCA Device2023|AFC ACCOMPLISHMENTS 113'