b'Figure 1. Temperature history of the 1200C oxidation test with coated Zircaloy-2 cladding sample for CP-ECR = 17%.Figure 2. (a) SEM overview of the mesoscale tensile bars cut in the C26M weld specimen (45 tilt). Comparison of the (b) engineering stress-strain curves, (c) tensile yield and ultimate strength, and (d) uniform elongation and tensile ductility measured in each region.76 2020|AFC ACCOMPLISHMENTS'